Lineman's Reference - XFMR LAB2.0.6 - App Store
You'll be able to see results in few seconds.
Publisher Description
Learn it. Wire it. Energize it. Check your work.
Built by a working journeyman lineman for linemen and their apprentices. The XFMR Lab simulates distribution transformer banks driven by your own wiring - the metering, fusing, and faulting all behave the way you'd expect in the field.
NEW IN 2.0 - BUILT-IN TRANSFORMER TRAINING (Replacing XFMR INFO)
Six guided lessons take you from "what's a transformer?" to wiring a 3-pot bank:
. Start Here - What is a Transformer?
. Dual H Bushings - The Two Wirings & the Nameplate
. The Tap Changer - One Pot, Multiple System Voltages
. Three-Phase - The Three Phases and How They're Related
. Bank Identification - Delta or Wye, Open or Closed
. Your First Bank: Delta-Wye Closed (120/208)
. More lessons on the way!
Work the lessons in order, or jump straight to the labs.
ALSO NEW IN 2.0
. The Sandbox (Beta) - wire anything from scratch in a COMPLETELY-customizable lab, with live, vector-based voltage and fault logic baked in.
. Death Traps - scenario-based transformer traps linemen run into - and how to navigate them safely.
. A brand-new look across every lab - new graphics, sharper, faster, & easier to read in the field.
. Voltmeter you can now drag with two fingers; readings update as the leads move.
. Parallel the secondary coils by hand in wye secondary labs
. Stats that track lab completions, quiz scoring and for-fun stuff like the number of fuses you've blown.
. User Customizations - the user can now alter the spec of their labs; from grounding to parallel coil cutover-direction, requiring the 4th cutout, tap changer implementation and more.
. 2.0 is FREE for everyone who already owns XFMR Lab - thank you for years of feedback and encouragement.
WHAT YOU GET
Single Phase - Single Bushing . Dual Bushing
Three Phase (closed) - Delta-Delta . Delta-Wye . Wye-Delta . Wye-Wye
Three Phase (open) - Open Delta-Delta . Open Wye-Delta
Misc - Paralleling . 4th Cutout . Death Traps (6 Scenarios)
Advanced - Straight 480 . 240/480 . 277/480 . Corner-Grounded 240/480 . Wye-Wye 5-Wire (120/240 + 120/208) - all now able to be wired up Wye AND Delta on the topside
The Sandbox (Beta)
EVERY FUTURE UPDATE IS FREE - THE APP IS A ONE-TIME PURCHASE. I'm always working on new updates.
TOOLS & REFERENCE
. Volt, ohm and rotation meters with real behavior
. Nameplate, secondary coil and tap changer animations
. Reference diagrams for every standard bank
Learning Mode walks apprentices through every wrong-connection check. Journeymen and experienced users can keep this turned off if they'd like.
QUIZZES
. Classic Quiz - Select each lab you want in your quiz - with graded scoring across each lab.
. Advanced Quiz - You're provided with the job-site info and need to pick the right nameplate and coil setup, then wire it.
. Bank ID - A beginner's quiz tied into the new XFMR Training lesson plan. The user is provided with different primary and secondary wirings and must correctly identify them.
Used by 30,000+ linemen since 2021.
Questions? Suggestions? Reach me at info@digitalapprentice.net
Version History Various bug fixes and feature polishing. 2.0.6 Sep 1 Various Bug Fixes. 2.0.5 Aug 9 New
• Amp clamp-on meter in the Sandbox: pull it out of the tool drawer, clamp it on any wire, and read the real current on that conductor. Try it on a loaded secondary leg (~100 A) vs. the primary jumper (~1.7 A), or on a 3-phase-loaded delta corner to catch the √3 between winding and line current.
• Fourth-cutout lab rebuilt as a guided, hands-on walkthrough. You energize the bank with the fourth cutout open and watch the ferroresonance blow happen, instead of just reading about it. Finishes with an unaided practice run you grade yourself.
• New customization option for starting Wye labs with the transformers already cut-over to the direction of your choice.
Improved
• If the app is waiting on Tutorial completion, tapping a locked button now tells you why and that it takes about 5 minutes. Longtime users upgrading from 1.x get a Skip Tutorial option after a quick look at what's new in 2.0.
• Learning Mode warning indicators now update live as you wire: the (!) flags appear and clear while you work, not only when you hit Check Work.
• The voltmeter steps out of the way while you drag a lead or draw a wire, then slides back so the reading stays visible.
• The correct-wiring diagram now shows the high leg on the phase you've actually set, instead of cycling through all three.
• Sandbox vector wheel now reads in the standard orientation (A at the 8 o'clock position) with a phase-displacement readout.
• Sharper splash screen update
Fixed
• Wire delete now works along the full length of every wire, including the ones that used to have dead spots, and no longer fires in the empty corner of an L-shaped run.
• Corner-ground and several banking labs no longer blow a fuse on some correct wirings.
• Voltages across the bank read true after a fuse blows, and a pot with its coils cut to series now reads the correct 240/120/120 split on wye labs.
• Banking nameplate always shows the correct primary voltage.
• Numerous other small bug fixes across each lab
(Existing users: thank you for the reports and feedback!) 2.0.4 Jul 28 XFMR Lab 2.0 — the biggest update since launch.
NEW: Built-in Transformer Training (replaces XFMR Info). Six guided lessons take you from "what's a transformer?" to wiring a 3-pot bank — Start Here, Dual H Bushings, The Tap Changer, Three-Phase, Bank Identification, and Your First Bank: Delta-Wye Closed. More lessons on the way. More lessons on the way soon!
NEW: The Sandbox (Beta) — wire anything from scratch in a fully customizable lab, with live, vector-based voltage and fault logic baked in.
NEW: Death Traps — scenario-based transformer traps linemen run into, and how to navigate them safely (3 scenarios with more on the way).
NEW: User Customizations — set the spec of your own labs: grounding, parallel coil cutover direction, requiring the 4th cutout, tap changers, and more.
NEW: Bank ID quiz — a beginner quiz tied to the Training lessons; identify primary and secondary wirings on sight.
NEW: Stats — track lab completions, quiz scores, and for-fun numbers like how many fuses you've blown.
ALSO:
• A brand-new look across every lab — new graphics, sharper and easier to read in the field.
• Tap changer, nameplate, and secondary coil animations.
• Parallel the secondary coils by hand in wye-secondary labs.
• Advanced labs can now be wired Wye OR Delta on the topside.
• Voltmeter now drags with two fingers; readings update as the leads move.
2.0 is FREE for everyone who already owns XFMR Lab — and every future update is free, too. One-time purchase. Thank you for years of feedback and encouragement. 2.0.3 Jul 4 Fixed a bug where rotation meter sometimes would not work properly. 1.3.02 02/10/2025 Fixed a minor bug in the Delta Delta Closed Bank lab. 1.3.01 02/09/2025 Added an advertisement for Lineman's Reference - URD 1.3.0 11/26/2024 Added POLETOP an advertisement. You can turn off advertisements in the settings on the homes screen settings. 1.2.23 07/20/2024 Couple of bug fixes. Thank you to those that reach out and bring things to my attention! 1.2.22 12/06/2023 Bug Fixes:
Bug where you couldn't use individual grounds for grounding secondary on 277/480 lab.
Ground straps missing on some diagrams. 1.2.21 11/20/2023 A new Advanced Quiz has been introduced. Test your transformer knowledge further! 1.2.20 09/07/2023 Fixed a couple of Typos. Added more info to 'Fusing' in XFMR INFO. 1.2.01 06/10/2023 Basics of Transformer Banking Lab. Various bug fixes. 1.2.0 06/06/2023 Fixed an issue found in the Dual Bushing Topside lab. 1.1.47 05/07/2023 Couple small bug fixes, new company added to the Customized Experience. 1.1.46 05/07/2023 A couple bug fixes:
Error with 277/480 diagram.
Error on Dual Bushing Topside lab's Nameplate. 1.1.44 02/02/2023 Updated Store Screenshots. 1.1.43 02/02/2023 New banks! Check the advanced tab in the Lab Menu to see 3 new labs! 1.1.42 01/26/2023 Minor changes and bug fixes. 1.1.4 12/03/2022 Updated Sound and Vibrate buttons in settings
Various Bug fixes
Implemented new background in all labs
Fixed issue with touching ground strap “through” wires
Fixed issue with Home Button not working when settings are visible in labs
Added “Hide Disclaimer at Start” option in Home Screen settings
Fixed an issue when Ohming in “Troubleshooting” 1.1.21 11/23/2022 Various Typos and Small Bug Fixes
Implementation of the Customized Experience for a company
New background for Home, Lab Menu, and Diagrams Menu 1.1.2 08/27/2022 Two new labs are available with the newest update! Test your transformers skills with Advanced Labs!
Wye 277/480 and Wye Wye with 120/240 service (5 wire service) are now available under the 'Advanced Labs' tab in the Lab Menu and Diagram Menu.
Proper NEC Standard secondary wire coloring.
Various Small Bug Fixes.
Company Customized Experience - ask your company to reach out to us! 1.0.19 05/21/2022 **UPDATES**
Added the ability to tie the secondaries on Delta secondary banks through the quadraplex. COOP compatible.
Added a button when inspecting the transformer to more easily cancel inspections.
Adjusted background color to make ground connections easier to see.
Updated the 'Info' button in the labs to include the current lab's objectives.
Updated the voltmeter with a rotation objective for the current lab when the 'Rotation Required' setting is active.
Fixed various inconstancies and mistakes with the nameplates and polarities. 1.0.18 04/03/2022 *NEW!*
Quiz Mode: Test your skills in quiz mode! Select how many labs you want in your quiz and receive a score at the end!
"Show Correct Wiring" Button: Now when you receive the "Try Again" message, there is an option to quickly reference the diagram for that lab.
Bug Fixes:
Volt meter has been completely re-written and is believed to be working perfectly.
Other random small bugs that were reported 1.0.16 01/19/2022 Updated a graphic in XFMR Info - Polarity that was incorrect.
Added a "rate this app!" button to the main menu. Please rate the app! 1.0.14 01/05/2022
About Lineman's Reference - XFMR LAB
The company that develops Lineman's Reference - XFMR LAB is Digital Apprentice LLC. The latest version released by its developer is 2.0.6.
To install Lineman's Reference - XFMR LAB on your iOS device, just click the green Continue To App button above to start the installation process. The app is listed on our website since 2026-10-15 and was downloaded 0 times. We have already checked if the download link is safe, however for your own protection we recommend that you scan the downloaded app with your antivirus. Your antivirus may detect the Lineman's Reference - XFMR LAB as malware if the download link is broken.
How to install Lineman's Reference - XFMR LAB on your iOS device:
- Click on the Continue To App button on our website. This will redirect you to the App Store.
- Once the Lineman's Reference - XFMR LAB is shown in the iTunes listing of your iOS device, you can start its download and installation. Tap on the GET button to the right of the app to start downloading it.
- If you are not logged-in the iOS appstore app, you'll be prompted for your your Apple ID and/or password.
- After Lineman's Reference - XFMR LAB is downloaded, you'll see an INSTALL button to the right. Tap on it to start the actual installation of the iOS app.
- Once installation is finished you can tap on the OPEN button to start it. Its icon will also be added to your device home screen.
Program Details
System requirements
Download information
Pricing
Version History
version 2.0.6
posted on 2026-10-15
Version History Various bug fixes and feature polishing. 2.0.6 Sep 1 Various Bug Fixes. 2.0.5 Aug 9 New
• Amp clamp-on meter in the Sandbox: pull it out of the tool drawer, clamp it on any wire, and read the real current on that conductor. Try it on a loaded secondary leg (~100 A) vs. the primary jumper (~1.7 A), or on a 3-phase-loaded delta corner to catch the √3 between winding and line current.
• Fourth-cutout lab rebuilt as a guided, hands-on walkthrough. You energize the bank with the fourth cutout open and watch the ferroresonance blow happen, instead of just reading about it. Finishes with an unaided practice run you grade yourself.
• New customization option for starting Wye labs with the transformers already cut-over to the direction of your choice.
Improved
• If the app is waiting on Tutorial completion, tapping a locked button now tells you why and that it takes about 5 minutes. Longtime users upgrading from 1.x get a Skip Tutorial option after a quick look at what's new in 2.0.
• Learning Mode warning indicators now update live as you wire: the (!) flags appear and clear while you work, not only when you hit Check Work.
• The voltmeter steps out of the way while you drag a lead or draw a wire, then slides back so the reading stays visible.
• The correct-wiring diagram now shows the high leg on the phase you've actually set, instead of cycling through all three.
• Sandbox vector wheel now reads in the standard orientation (A at the 8 o'clock position) with a phase-displacement readout.
• Sharper splash screen update
Fixed
• Wire delete now works along the full length of every wire, including the ones that used to have dead spots, and no longer fires in the empty corner of an L-shaped run.
• Corner-ground and several banking labs no longer blow a fuse on some correct wirings.
• Voltages across the bank read true after a fuse blows, and a pot with its coils cut to series now reads the correct 240/120/120 split on wye labs.
• Banking nameplate always shows the correct primary voltage.
• Numerous other small bug fixes across each lab
(Existing users: thank you for the reports and feedback!) 2.0.4 Jul 28 XFMR Lab 2.0 — the biggest update since launch.
NEW: Built-in Transformer Training (replaces XFMR Info). Six guided lessons take you from "what's a transformer?" to wiring a 3-pot bank — Start Here, Dual H Bushings, The Tap Changer, Three-Phase, Bank Identification, and Your First Bank: Delta-Wye Closed. More lessons on the way. More lessons on the way soon!
NEW: The Sandbox (Beta) — wire anything from scratch in a fully customizable lab, with live, vector-based voltage and fault logic baked in.
NEW: Death Traps — scenario-based transformer traps linemen run into, and how to navigate them safely (3 scenarios with more on the way).
NEW: User Customizations — set the spec of your own labs: grounding, parallel coil cutover direction, requiring the 4th cutout, tap changers, and more.
NEW: Bank ID quiz — a beginner quiz tied to the Training lessons; identify primary and secondary wirings on sight.
NEW: Stats — track lab completions, quiz scores, and for-fun numbers like how many fuses you've blown.
ALSO:
• A brand-new look across every lab — new graphics, sharper and easier to read in the field.
• Tap changer, nameplate, and secondary coil animations.
• Parallel the secondary coils by hand in wye-secondary labs.
• Advanced labs can now be wired Wye OR Delta on the topside.
• Voltmeter now drags with two fingers; readings update as the leads move.
2.0 is FREE for everyone who already owns XFMR Lab — and every future update is free, too. One-time purchase. Thank you for years of feedback and encouragement. 2.0.3 Jul 4 Fixed a bug where rotation meter sometimes would not work properly. 1.3.02 02/10/2025 Fixed a minor bug in the Delta Delta Closed Bank lab. 1.3.01 02/09/2025 Added an advertisement for Lineman's Reference - URD 1.3.0 11/26/2024 Added POLETOP an advertisement. You can turn off advertisements in the settings on the homes screen settings. 1.2.23 07/20/2024 Couple of bug fixes. Thank you to those that reach out and bring things to my attention! 1.2.22 12/06/2023 Bug Fixes:
Bug where you couldn't use individual grounds for grounding secondary on 277/480 lab.
Ground straps missing on some diagrams. 1.2.21 11/20/2023 A new Advanced Quiz has been introduced. Test your transformer knowledge further! 1.2.20 09/07/2023 Fixed a couple of Typos. Added more info to 'Fusing' in XFMR INFO. 1.2.01 06/10/2023 Basics of Transformer Banking Lab. Various bug fixes. 1.2.0 06/06/2023 Fixed an issue found in the Dual Bushing Topside lab. 1.1.47 05/07/2023 Couple small bug fixes, new company added to the Customized Experience. 1.1.46 05/07/2023 A couple bug fixes:
Error with 277/480 diagram.
Error on Dual Bushing Topside lab's Nameplate. 1.1.44 02/02/2023 Updated Store Screenshots. 1.1.43 02/02/2023 New banks! Check the advanced tab in the Lab Menu to see 3 new labs! 1.1.42 01/26/2023 Minor changes and bug fixes. 1.1.4 12/03/2022 Updated Sound and Vibrate buttons in settings
Various Bug fixes
Implemented new background in all labs
Fixed issue with touching ground strap “through” wires
Fixed issue with Home Button not working when settings are visible in labs
Added “Hide Disclaimer at Start” option in Home Screen settings
Fixed an issue when Ohming in “Troubleshooting” 1.1.21 11/23/2022 Various Typos and Small Bug Fixes
Implementation of the Customized Experience for a company
New background for Home, Lab Menu, and Diagrams Menu 1.1.2 08/27/2022 Two new labs are available with the newest update! Test your transformers skills with Advanced Labs!
Wye 277/480 and Wye Wye with 120/240 service (5 wire service) are now available under the 'Advanced Labs' tab in the Lab Menu and Diagram Menu.
Proper NEC Standard secondary wire coloring.
Various Small Bug Fixes.
Company Customized Experience - ask your company to reach out to us! 1.0.19 05/21/2022 **UPDATES**
Added the ability to tie the secondaries on Delta secondary banks through the quadraplex. COOP compatible.
Added a button when inspecting the transformer to more easily cancel inspections.
Adjusted background color to make ground connections easier to see.
Updated the 'Info' button in the labs to include the current lab's objectives.
Updated the voltmeter with a rotation objective for the current lab when the 'Rotation Required' setting is active.
Fixed various inconstancies and mistakes with the nameplates and polarities. 1.0.18 04/03/2022 *NEW!*
Quiz Mode: Test your skills in quiz mode! Select how many labs you want in your quiz and receive a score at the end!
"Show Correct Wiring" Button: Now when you receive the "Try Again" message, there is an option to quickly reference the diagram for that lab.
Bug Fixes:
Volt meter has been completely re-written and is believed to be working perfectly.
Other random small bugs that were reported 1.0.16 01/19/2022 Updated a graphic in XFMR Info - Polarity that was incorrect.
Added a "rate this app!" button to the main menu. Please rate the app! 1.0.14 01/05/2022
Disclaimer
Official App Store Link
We do not host Lineman's Reference - XFMR LAB on our servers. We did not scan it for viruses, adware, spyware or other type of malware. This app is hosted by Apple and passed their terms and conditions to be listed there. We recommend caution when installing it.
The App Store link for Lineman's Reference - XFMR LAB is provided to you by apps112.com without any warranties, representations or guarantees of any kind, so access it at your own risk.
If you have questions regarding this particular app contact the publisher directly. For questions about the functionalities of apps112.com contact us.